The Q Acoustics QI65LCRF is a fire and acoustic hood designed specifically for the QI65LCR in-ceiling speaker. A legal requirement in many new-build properties, fire hoods maintain the integrity of ceiling fire ratings where speakers are installed, ensuring compliance with UK Building Regulations Part B (Fire Safety) and Part E (Sound Insulation). Tested at the UK Building Test Centre, the QI65LCRF preserves either a 30-minute or 60-minute fire rating depending on the ceiling construction.
Fire Protection
The hood is constructed from woven glass fabric with a thickness of 0.40mm and a weight of 430 g/m², finished with a starch weave lock. This fire-resistant material has a flash ignition point of 315–370°C and an auto-ignition point of 370–427°C, with stable operation across a wide temperature range of −40°C to +120°C. The warp count of 1360 d’tex provides the structural integrity needed to maintain the ceiling’s fire barrier around the speaker cut-out.
Acoustic Isolation
Beyond fire protection, the QI65LCRF also acts as an acoustic barrier, reducing rear sound transmission by approximately 10dB in mid-to-high frequencies. This is particularly useful in multi-storey properties, flats, and HMOs where sound bleed between floors needs to be minimised. The internal sponge lining absorbs rear-radiated energy from the speaker driver, preventing it from transmitting through the ceiling void into adjacent rooms.
Installation
The QI65LCRF fits directly over the rear of the QI65LCR in-ceiling speaker once it is mounted in the ceiling. The hood’s 270 × 540mm footprint with a depth of 110mm accommodates the speaker’s backbox requirements while leaving sufficient clearance for cable routing and ventilation.
Q Acoustics Fire Hood Range
Q Acoustics offers a complete range of fire and acoustic hoods to match their in-ceiling and in-wall speaker line-up. The QI50CF suits the QI50 and IC125, the QI65CF fits the QI65 and IC165, the QI80CF covers the QI80 and QI80 SUB, and dedicated rectangular hoods (QI65RF and QI80RF) are available for the QI65R and QI80R in-wall models respectively.
| Compatible Speaker | Q Acoustics QI65LCR |
| Fire Rating | 30 or 60 minutes (depending on ceiling construction) |
| Sound Reduction | Up to 10dB (mid-to-high frequencies) |
| Compliance | UK Building Regulations Part B & Part E |
| Fabric Material | Woven glass fabric |
| Fabric Thickness | 0.40mm |
| Fabric Weight | 430 g/m² |
| Warp Count | 1360 d’tex |
| Finish | Starch weave lock |
| Flash Ignition Point | 315–370°C |
| Auto-Ignition Point | 370–427°C |
| Operating Temperature | −40°C to +120°C |
| Dimensions | 270 × 540mm |
| Depth | 110mm |
| Also Available As | QI50CF (for QI50 & IC125), QI65CF (for QI65 & IC165), QI80CF (for QI80 & QI80 SUB), QI65RF (for QI65R), QI80RF (for QI80R) |